< Previous
Next >
NEUTRAL SWITCH INSPECTION [SKYACTIV-G 2.0]
Continuity Inspection
1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)
2. Remove the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION [M66M-D].)
3. Inspect for continuity between neutral switch terminal A and D.< Previous Next >Specification
If not as specified, replace the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION [M66M-D].)
Measured condition
Continuity
Rod pushed
Continuity detected
Rod not pushed
No continuity