< Previous
Next >
DOWN SWITCH INSPECTION [SJ6A-EL]
Continuity Inspection
NOTE:
The down position switch is built into the selector lever component.
1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)
2. Remove the following parts:a. Selector lever knob (See AUTOMATIC TRANSMISSION SHIFT MECHANISM REMOVAL/INSTALLATION.)b. Shift panel component (See SHIFT PANEL REMOVAL/INSTALLATION.)
3. Disconnect the selector lever component connector.
4. Verify that the continuity between selector lever component terminals D and H.< Previous Next >Down position switch specification
If not as verified, replace the selector lever component. (See AUTOMATIC TRANSMISSION SHIFT MECHANISM REMOVAL/INSTALLATION.)
Test condition
Continuity
Selector lever is in the M position (−) side position.
Continuity
Selector lever is not in the M position (−) side position.
No continuity