< Previous
Next >
NOT P POSITION SWITCH INSPECTION
NOTE:
The not P position switch is built into the selector lever component.
1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)
2. Remove the following parts:a. Selector lever knob (See AUTOMATIC TRANSMISSION SHIFT MECHANISM REMOVAL/INSTALLATION.)b. Shift panel component (See SHIFT PANEL REMOVAL/INSTALLATION.)
3. Disconnect the selector lever component connector.
4. Verify that the continuity between selector lever component terminals B and G.< Previous Next >Not P position switch specification
If not as verified, replace the selector lever component. (See AUTOMATIC TRANSMISSION SHIFT MECHANISM REMOVAL/INSTALLATION.)
Test condition
Continuity
Selector lever is in the P position.
No continuity
Selector lever is not in the P position.
Continuity