INSUFFICIENT AIR (OR NO AIR) BLOWN FROM VENTS [CLIMATE CONTROL SYSTEM]
DESCRIPTION |
|
POSSIBLE CAUSE |
|
When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions.
If there is a problem, check to make sure connectors, terminals and wiring harnesses are connected correctly and undamaged.
Diagnostic Procedure
Step |
Inspection |
Action |
|
1 |
INSPECT FUSE
|
Yes |
Go to the next step. |
No |
If the fuse is melted: Repair or replace wiring harness for short to ground and replace the fuse. If the fuse is deterioration: Replace the fuse. Then go to Step 19. |
||
2* |
INSPECT TO SEE WHETHER MALFUNCTION (OPEN CIRCUIT) IS IN B+ SIGNAL WIRING HARNESS (BETWEEN FUSE BLOCK AND CLIMATE CONTROL UNIT) OR ELSEWHERE
|
Yes |
Go to the next step. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and fuse block terminal.
Go to the Step 19. |
||
3* |
INSPECT TO SEE WHETHER MALFUNCTION IS IN A/C UNIT OR AIRFLOW MODE ACTUATOR
|
Yes |
Go to Step 15. |
No |
Go to the next step. |
||
4* |
INSPECT TO SEE WHETHER MALFUNCTION IS IN POSITION SENSOR OR ELSEWHERE
|
Yes |
Go to Step 7. |
No |
Go to the next step. |
||
5* |
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY OR SHORT TO POWER SUPPLY OR GROUND) IS IN POSITION SENSOR POWER SUPPLY OR ELSEWHERE
|
Yes |
Go to the next step. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and airflow mode actuator / air mix actuator terminal.
Go to Step 19. |
||
6* |
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY OR OPEN CIRCUIT) IS IN POSITION SENSOR GROUND OR ELSEWHERE
|
Yes |
Go to Step 10. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and airflow mode actuator / air mix actuator terminal.
Go to Step 19. |
||
7* |
INSPECT TO SEE WHETHER MALFUNCTION (SHORT TO POWER SUPPLY) IS IN WIRING HARNESS (AIRFLOW MODE POSITION SIGNAL) OR ELSEWHERE
|
Yes |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and airflow mode actuator terminal.
Go to the Step 19. |
No |
Go to the next step. |
||
8* |
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN WIRING HARNESS (AIRFLOW MODE POSITION SIGNAL) OR ELSEWHERE
|
Yes |
Go to the next step. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and airflow mode actuator terminal.
Go to Step 19. |
||
9* |
INSPECT TO SEE WHETHER MALFUNCTION (SHORT TO GROUND) IS IN WIRING HARNESS (AIRFLOW MODE POSITION SIGNAL) OR POSITION SENSOR COMMON (POWER SUPPLY OR GROUND) HARNESS
|
Yes |
Repair wiring harness between climate control unit terminal and airflow mode actuator terminal. Then go to Step 19. |
No |
Inspection and repair for open circuit following:
Then go to Step 19. |
||
10* |
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN AIRFLOW MODE ACTUATOR WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIRFLOW MODE ACTUATOR) OR ELSEWHERE
|
Yes |
Go to the next step. |
No |
Go to Step 12. |
||
11* |
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN AIRFLOW MODE ACTUATOR OR WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIRFLOW MODE ACTUATOR)
|
Yes |
Go to Step 15. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and airflow mode actuator terminal.
Go to Step 19. |
||
12* |
INSPECT TO SEE WHETHER MALFUNCTION IS IN AIRFLOW MODE ACTUATOR OR ELSEWHERE
|
Yes |
Go to Step 15. |
No |
Go to the next step. |
||
13* |
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO B+ BETWEEN CLIMATE CONTROL UNIT AND AIRFLOW MODE ACTUATOR) OR ELSEWHERE
|
Yes |
Go to the next step. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and airflow mode actuator terminal.
Go to the Step 19. |
||
14* |
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO GROUND BETWEEN CLIMATE CONTROL UNIT AND AIRFLOW MODE ACTUATOR) OR ELSEWHERE
|
Yes |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and airflow mode actuator terminal.
Go to the Step 19. |
No |
Go to the next step. |
||
15 |
INSPECT AIRFLOW MODE ACTUATOR
|
Yes |
Go to the next step. |
No |
Replace the airflow mode actuator. (See AIRFLOW MODE ACTUATOR REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].) (See AIRFLOW MODE ACTUATOR REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER].) Then go to the Step 19. |
||
16 |
INSPECT AIRFLOW MODE LINK
|
Yes |
Go to the next step. |
No |
Apply grease to links. If any links are damaged, replace malfunctioning part. Then go to the Step 19. |
||
17 |
INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR AIRFLOW MODE DOOR
|
Yes |
Go to the next step. |
No |
Remove the obstruction, or install door in proper position. If any doors are cracked or damaged, replace them. Then go to the Step 19. |
||
18 |
VERIFY DUCT INSTALLATION CONDITION
|
Yes |
Inspect ducts for restriction, deformity, and air leakage, then go to the next step. |
No |
Install the incorrectly installed ducts properly, then go to the next step. |
||
19 |
VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR
|
Yes |
Troubleshooting completed. Explain repairs to customer. |
No |
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs. |