NO TEMPERATURE CONTROL WITH CLIMATE CONTROL UNIT [CLIMATE CONTROL SYSTEM]
DESCRIPTION |
|
POSSIBLE CAUSE |
|
When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions.
If there is a problem, check to make sure connectors, terminals and wiring harnesses are connected correctly and undamaged.
Diagnostic Procedure
Step |
Inspection |
Action |
|
1 |
INSPECT COOLANT TEMPERATURE
|
Yes |
Go to the next step. |
No |
Warm up the engine, then go to Step 19. |
||
2* |
INSPECT FUSE
|
Yes |
Go to the next step. |
No |
If the fuse is melted: Repair or replace wiring harness for short to ground and replace the fuse. If the fuse is deterioration: Replace the fuse. Then go to Step 19. |
||
3* |
INSPECT TO SEE WHETHER MALFUNCTION (OPEN CIRCUIT) IS IN B+ SIGNAL WIRING HARNESS (BETWEEN FUSE BLOCK AND CLIMATE CONTROL UNIT) OR ELSEWHERE
|
Yes |
Go to the next step. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between fuse block terminal and climate control unit terminal.
Go to Step 19. |
||
4* |
INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR AIR MIX ACTUATOR
|
Yes |
Go to Step 15. |
No |
Go to the next step. |
||
5* |
INSPECT TO SEE WHETHER MALFUNCTION IS IN POSITION SENSOR OR ELSEWHERE
|
Yes |
Go to Step 8. |
No |
Go to the next step. |
||
6* |
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY OR SHORT TO BATTERY POWER OR GROUND) IS IN POSITION SENSOR POWER SUPPLY OR ELSEWHERE
|
Yes |
Go to the next step. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.
Go to Step 19. |
||
7* |
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY OR OPEN) IS IN POSITION SENSOR GROUND OR ELSEWHERE
|
Yes |
Go to Step 11. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.
Go to Step 19. |
||
8 |
INSPECT TO SEE WHETHER MALFUNCTION (SHORT TO POWER SUPPLY) IS IN WIRING HARNESS (AIR MIX POSITION SIGNAL) OR ELSEWHERE
|
Yes |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.
Go to Step 19. |
No |
Go to the next step. |
||
9* |
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN WIRING HARNESS (AIR MIX POSITION SIGNAL) OR ELSEWHERE
|
Yes |
Go to the next step. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and each side air mix actuator terminal.
Go to Step 19. |
||
10* |
INSPECT TO SEE WHETHER MALFUNCTION (SHORT TO GROUND) IS IN WIRING HARNESS (AIR MIX POSITION SIGNAL) OR POSITION SENSOR COMMON (POWER SUPPLY OR GROUND) HARNESS
|
Yes |
Repair wiring harness for short to ground between climate control unit and air mix actuator. Then go to Step 19. |
No |
Inspect and repair for open circuit following:
Then go to Step 19. |
||
11* |
INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN AIR MIX ACTUATOR OR WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR)
|
Yes |
Go to Step 15. |
No |
Go to the next step. |
||
12* |
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO B+ BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
|
Yes |
Go to the next step. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.
Go to Step 19. |
||
13* |
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO GROUND BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
|
Yes |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.
Go to Step 19. |
No |
Go to the next step. |
||
14* |
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY OR OPEN BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
|
Yes |
Go to the next step. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.
Go to Step 19. |
||
15 |
INSPECT AIR MIX ACTUATOR
|
Yes |
Go to the next step. |
No |
Replace the air mix actuator. Then go to 19. (See AIR MIX ACTUATOR REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].) (See AIR MIX ACTUATOR REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER].) |
||
16 |
INSPECT AIR MIX GEAR
|
Yes |
Go to the next step. |
No |
Apply grease to gear. If any gear is damaged. Replace malfunctioning part. (See A/C UNIT DISASSEMBLY/ASSEMBLY.) Then go to Step 19. |
||
17 |
INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR AIR MIX DOOR ELSEWHERE
|
Yes |
Go to the next step. |
No |
Remove the obstruction, or install door in proper position. If any door are cracked, replace them. (See A/C UNIT DISASSEMBLY/ASSEMBLY.) Then go to the next step. |
||
18 |
INSPECT HEATER HOSE
|
Yes |
Replace the climate control unit. Then go to the next step. (See CLIMATE CONTROL UNIT REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].) (See CLIMATE CONTROL UNIT REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER].) |
No |
If heater hoses connections are loose, install securely in the correct position. Repair or replace the heater hoses. (See HEATER HOSE REMOVAL/INSTALLATION.) Then go to the next step. |
||
19 |
VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR
|
Yes |
Troubleshooting completed. Explain repairs to customer. |
No |
Recheck malfunction symptoms, then repeat from Step1 if the malfunction recurs. |