DETERMINING SHORT BETWEEN CIRCUITS LOCATION (MS-CAN)
CAUTION:
Perform the following malfunction diagnosis only when it is diagnosed with a short between circuits by CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW. (See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW.)
System Wiring Diagram
Determination Procedure
CAUTION:
When disconnecting the connector, verify that there is no looseness, damage, deformation, corrosion, or poor connection of the connector terminals.
When inspecting the DLC-2, touch it with a paper clip or similar thin pin without directly inserting a tester into the terminals.
Step |
Inspection |
Action |
|
1 |
INSPECT BETWEEN INSTRUMENT CLUSTER AND CONNECTOR C-40 FOR SHORT BETWEEN CIRCUITS
|
Yes |
Go to the next step. |
No |
Go to Step 3. |
||
2 |
INSPECT INSTRUMENT CLUSTER FOR SHORT BETWEEN CIRCUITS
|
Yes |
Repair or replace the wiring harness between the instrument cluster and connector C-40 because the wiring harness is shorted between circuits. |
No |
Replace the instrument cluster because there is a short between circuits in the instrument cluster. |
||
3 |
INSPECT BETWEEN CONNECTOR C-40 AND DLC-2 FOR SHORT BETWEEN CIRCUITS
|
Yes |
Repair or replace the wiring harness between connector C-40 and DLC-2 because the wiring harness is shorted between circuits. |
No |
Go to the next step. |
||
4 |
INSPECT BETWEEN CONNECTOR C-40 AND CONNECTOR C-14 FOR SHORT BETWEEN CIRCUITS
|
Yes |
Repair or replace the wiring harness between connector C-40 and connector C-14 because the wiring harness is shorted between circuits. |
No |
Go to the next step. |
||
5 |
INSPECT BETWEEN CLIMATE CONTROL UNIT AND CONNECTOR C-14 FOR SHORT BETWEEN CIRCUITS
|
Yes |
Go to Step 8. |
No |
Go to the next step. |
||
6 |
INSPECT BETWEEN BLIND SPOT MONITORING (BSM) CONTROL MODULE (LH) AND CONNECTOR C-26 FOR SHORT BETWEEN CIRCUITS
|
Yes |
Go to the next step. |
No |
Repair or replace the wiring harness between connector C-14 and connector C-26 because the wiring harness is shorted between circuits. |
||
7 |
INSPECT BLIND SPOT MONITORING (BSM) CONTROL MODULE (LH) FOR SHORT BETWEEN CIRCUITS
|
Yes |
Repair or replace the wiring harness between the blind spot monitoring (BSM) control module (LH) and connector C-26 because the wiring harness is shorted between circuits. |
No |
Replace the blind spot monitoring (BSM) control module (LH) because there is a short between circuits in the blind spot monitoring (BSM) control module (LH). (See BLIND SPOT MONITORING (BSM) CONTROL MODULE REMOVAL/INSTALLATION.) |
||
8 |
INSPECT CLIMATE CONTROL UNIT FOR SHORT BETWEEN CIRCUITS
|
Yes |
Repair or replace the wiring harness between the climate control unit and connector C-14 because the wiring harness is shorted between circuits. |
No |
Replace the climate control unit because there is a short between circuits inside the climate control unit. (See CLIMATE CONTROL UNIT REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].) (See CLIMATE CONTROL UNIT REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER].) |