DTC B1175:11 [BCM]
Description |
Door latch switch (LH) circuit malfunction |
Detection condition |
|
Fail-safe |
Not applicable |
Possible cause |
|
Step |
Inspection |
Action |
|
1 |
VERIFY BCM DTCs AGAIN
|
Yes |
Go to the next step. |
No |
Go to Step 7. |
||
2 |
INSPECT DOOR LATCH AND LOCK ACTUATOR (LH) CONNECTOR CONDITION
|
Yes |
Go to the next step. |
No |
Repair or replace the connector, then go to Step 6. |
||
3 |
INSPECT DOOR LATCH SWITCH (LH)
|
Yes |
Go to the next step. |
No |
Replace the door latch and lock actuator (LH), then go to Step 6. |
||
4 |
INSPECT BCM CONNECTOR CONDITION
|
Yes |
Go to the next step. |
No |
Repair or replace the connector, then go to Step 6. |
||
5 |
INSPECT DOOR LATCH SWITCH (LH) CIRCUIT FOR SHORT TO GROUND
|
Yes |
Refer to the wiring diagram and verify whether or not there is a common connector between door latch and lock actuator (LH) terminal L and BCM terminal 2H.
Go to the next step. |
No |
Go to the next step. |
||
6 |
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes |
Repeat the inspection from Step 1.
Go to the next step. |
No |
Go to the next step. |
||
7 |
VERIFY IF OTHER DTCs DISPLAYED
|
Yes |
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [BCM].) |
No |
DTC troubleshooting completed. |