< Previous
Next >
FUEL-FILLER LID LOCK ACTUATOR INSPECTION
1. Open the fuel-filler lid.
2. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)
3. Remove the trunk end trim. (See TRUNK END TRIM REMOVAL/INSTALLATION.)
4. Partially peel back the trunk side trim (LH) to the position allowing removal of the fuel-filler lid lock actuator. (See TRUNK SIDE TRIM REMOVAL/INSTALLATION.)
5. Disconnect the fuel-filler lid lock actuator connector. (See FUEL-FILLER LID LOCK ACTUATOR REMOVAL/INSTALLATION.)
6. Apply battery positive voltage and connect the ground to the fuel-filler lid lock actuator terminals as indicated in the table below and verify the operation condition.< Previous Next >
B+ terminal
Ground terminal
Operation
A
B
Lock
B
A
Unlock
If not as indicated in the table, replace the fuel-filler lid lock actuator. (See FUEL-FILLER LID LOCK ACTUATOR REMOVAL/INSTALLATION.)