DTC P2503:00 [PCM (SKYACTIV-G 2.0)]
NOTE:
To determine the malfunctioning part, proceed with the diagnostics from "Function Inspection Using M-MDS".
Details On DTCs
DESCRIPTION |
Generator system: Voltage generated by generator is low |
|
DETECTION CONDITION |
Determination conditions |
|
Preconditions |
|
|
Malfunction determination period |
|
|
Drive cycle |
|
|
Self test type |
|
|
Sensor used |
|
|
FAIL-SAFE FUNCTION |
|
|
VEHICLE STATUS WHEN DTCs ARE OUTPUT |
|
|
POSSIBLE CAUSE |
|
System Wiring Diagram
Function Explanation (DTC Detection Outline)
When the charge/discharge circuit for the power supplying the vehicle is normal, the vehicle will operate normally.
Although a power generation command is made to the generator, a malfunction is diagnosed indicating no output from the generator, and verification of vehicle malfunctions/safety assurance is performed.
Repeatability Verification Procedure
Clear the DTC from the PCM memory using the M-MDS. (See CLEARING DTC [PCM (SKYACTIV-G 2.0)].)
Start the engine.
Leave for 30 s while idling with high electrical load.
PID Item/Simulation Item Used In Diagnosis
Not applicable
Function Inspection Using M-MDS
STEP |
INSPECTION |
RESULTS |
ACTION |
1 |
PURPOSE: RECORD VEHICLE STATUS AT TIME OF DTC DETECTION TO UTILIZE WITH REPEATABILITY VERIFICATION NOTE:
|
— |
Go to the troubleshooting procedure to perform the procedure from Step 1. |
Troubleshooting Diagnostic Procedure
Intention of troubleshooting procedure
Step 1—6
Perform an inspection of each signal transmission system.
Step 7
Perform a generator drive belt related inspection.
Step 8
Perform a unit inspection of the generator.
Step 9—11
Verify that the primary malfunction is resolved and there are no other malfunctions.
STEP |
INSPECTION |
RESULTS |
ACTION |
1 |
PURPOSE: VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes |
Perform repair or diagnosis according to the available repair information.
|
No |
Go to the next step. |
||
2 |
PURPOSE: VERIFY IF POOR CONNECTION OF EACH PART AFFECTS DIAGNOSTIC RESULTS
|
Yes |
Go to the next step. |
No |
Connect each part or the connector correctly, then go to Step 9. |
||
3 |
PURPOSE: VERIFY IF CONNECTOR DAMAGE OF EACH PART AFFECTS DIAGNOSTIC RESULTS
|
Yes |
Repair or replace the connector and/or terminals, then go to Step 9. |
No |
Go to the next step. |
||
4 |
PURPOSE: INSPECT FUSE
|
Yes |
If the fuse is blown:
If the fuse is damaged:
Go to Step 9. |
No |
Reinstall the STR/ALT 200 A fuse, then go to the next step. |
||
5 |
PURPOSE: VERIFY IF SHORT TO GROUND IN EACH WIRING HARNESS AFFECTS DIAGNOSTIC RESULTS
|
Yes |
Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
Go to Step 9. |
No |
Go to the next step. |
||
6 |
PURPOSE: VERIFY IF OPEN CIRCUIT IN EACH WIRING HARNESS AFFECTS DIAGNOSTIC RESULTS
|
Yes |
Go to the next step. |
No |
Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
Go to Step 9. |
||
7 |
PURPOSE: VERIFY IF MALFUNCTION RELATED TO GENERATOR DRIVE BELT AFFECTS DIAGNOSTIC RESULTS
|
Yes |
Go to the next step. |
No |
Replace the generator drive belt, then go to the next step. |
||
8 |
PURPOSE: DETERMINE INTEGRITY OF GENERATOR
|
Yes |
Replace the generator, then go to the next step. |
No |
Go to the next step. |
||
9 |
PURPOSE: VERIFY CONDITIONS OF BATTERY
|
— |
Follow the inspection instructions, then go to the next step. |
10 |
PURPOSE: VERIFICATION OF VEHICLE REPAIR COMPLETION
|
Yes |
Repeat the inspection from Step 1.
Go to the next step. |
No |
Go to the next step. |
||
11 |
PURPOSE: VERIFY IF THERE IS ANY OTHER MALFUNCTION
|
Yes |
Go to the applicable DTC inspection. |
No |
DTC troubleshooting completed. |