AIR FROM VENTS NOT COLD ENOUGH [CLIMATE CONTROL SYSTEM]
DESCRIPTION |
|
POSSIBLE CAUSE |
NOTE:
|
Step |
Inspection |
Action |
|
1 |
INSPECT CLIMATE CONTROL UNIT FOR DTC
|
Yes |
Go to the applicable DTC troubleshooting procedures. (See DTC TABLE [CLIMATE CONTROL UNIT (FULL-AUTO AIR CONDITIONER)].) (See DTC TABLE [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)].) |
No |
Go to the next step. |
||
2 |
INSPECT REFRIGERANT PRESSURE TO LOCATE MALFUNCTION
|
Yes |
Go to the next step. |
No |
Record the inspection result.
|
||
3 |
INSPECT REFRIGERANT SYSTEM PERFORMANCE
|
Yes |
Operation is normal. (Recheck malfunction symptoms.) |
No |
Go to the next step. |
||
4 |
INSPECT DRIVE BELT
|
Yes |
Go to the next step. |
No |
Adjust or replace the drive belt, then the next step. |
||
5 |
INSPECT REFRIGERANT PRESSURE SENSOR
|
Yes |
Go to the next step. |
No |
Repair or replace malfunctioning part according to inspection result, then go to Step 21. |
||
6 |
INSPECT COOLING FAN OPERATION
|
Yes |
Go to the next step. |
No |
Repair or replace the malfunctioning location according to the inspection results. Then go to Step 21. |
||
7 |
VISUALLY INSPECT CONDENSER
|
Yes |
Remove the foreign material. Repair the condenser fin. Then go to Step 21. |
No |
Go to the next step. |
||
8 |
CHECK REFRIGERATION SYSTEM FOR OVERCHARGE OR AIR CONTAMINATION
|
Yes |
Recover refrigerant. Evacuate system for one hour. Refill with correct amount of refrigerant, and go to step 21. |
No |
Recover refrigerant, evacuate for 15 minutes, refill with correct amount and go to step 21. |
||
9 |
CHECK TO SEE WHETHER MALFUNCTION IS IN EXPANSION VALVE OR ELSEWHERE
|
Yes |
Replace the expansion valve. After performing the following servicing, go to Step 21.
|
No |
Go to the next step. |
||
10 |
INSPECT AIR MIX DOOR RELATED PART INSTALLATION
|
Yes |
Adjust the compressor oil to the specified amount, then go to Step 21. |
No |
|
||
11 |
INSPECT A/C UNIT FOR BLOCKAGE
|
Yes |
Remove the cause of the clogging. Replace the dust filter if it is clogged. (See DUST FILTER REMOVAL/INSTALLATION.) Then go to Step 21. |
No |
Go to the next step. |
||
12 |
CHECK TO SEE WHETHER MALFUNCTION IS REFRIGERANT LINE LEAKAGE OR ELSEWHERE
|
Yes |
|
No |
Go to the next step. |
||
13 |
VISUALLY INSPECT REFRIGERANT LINE
|
Yes |
Replace the crushed system hose. (See REFRIGERANT LINE REMOVAL/INSTALLATION.) After performing the following servicing, go to Step 21.
|
No |
Go to Step 20. |
||
14 |
CHECK TO SEE WHETHER MALFUNCTION IS IN REFRIGERANT LINE JOINT LOOSE OR O-RING
|
Yes |
Go to the next step. |
No |
Go to Step 16. |
||
15 |
VISUALLY INSPECT REFRIGERANT LINE
|
Yes |
Replace the crushed system hose. (See REFRIGERANT LINE REMOVAL/INSTALLATION.) After performing the following servicing, go to Step 21.
|
No |
Adjust the compressor oil to the specified amount, then go to Step 21. |
||
16 |
VISUALLY INSPECT REFRIGERANT LINE
|
Yes |
Replace the O-ring of the leaking area. Replace the crushed system hose. (See REFRIGERANT LINE REMOVAL/INSTALLATION.) After performing the following servicing, go to Step 21.
|
No |
Replace the O-ring of the leaking area. After performing the following servicing, go to Step 21.
|
||
17 |
CHECK TO SEE WHETHER MALFUNCTION IS WATER IN REFRIGERANT SYSTEM OR ELSEWHERE
|
Yes |
Replace the condenser. (Water in refrigerant system) (See CONDENSER REMOVAL/INSTALLATION.) Go to Step 21. |
No |
Go to the next step. |
||
18 |
CHECK TO SEE WHETHER MALFUNCTION IS IN RECEIVER DRYER FILTER OR EXPANSION VALVE
|
Yes |
If there is foreign matter clogging the valve:
If there is refrigerant leakage or clogging:
Perform discharge, charge with new refrigerant, and then go to Step 21. |
No |
Replace the condenser. (Receiver/Dryer filter is clogged.) (See CONDENSER REMOVAL/INSTALLATION.) Then go to Step 21. |
||
19 |
INSPECT EVAPORATIVE TEMPERATURE SENSOR
|
Yes |
Verify the evaporator temperature sensor position. (See A/C UNIT DISASSEMBLY/ASSEMBLY.) Then go to Step 21. |
No |
Replace the evaporator temperature sensor. (See A/C UNIT DISASSEMBLY/ASSEMBLY.) Then go to Step 21. |
||
20 |
INSPECT AIR MIX DOOR RELATED PART INSTALLATION
|
Yes |
Go to the next step. |
No |
|
||
21 |
VERIFY THAT MALFUNCTION SYMPTOM DOES OCCURS AFTER REPAIR
|
Yes |
Troubleshooting completed. Explain repairs to customer. |
No |
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs. |