DTC U2300:54 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
Description |
Configuration data not received from instrument cluster |
Detection condition |
|
Fail-safe |
|
Possible cause |
NOTE:
|
System wiring diagram |
Not applicable |
Step |
Inspection |
Action |
|
1 |
VERIFY INSTRUMENT CLUSTER DTCs
|
Yes |
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. |
No |
Go to the next step. |
||
2 |
RESET INSTRUMENT CLUSTER CONFIGURATION DATA
|
Yes |
Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step. (See INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA).) |
No |
Go to Step 4. |
||
3 |
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes |
Replace the blind spot monitoring (BSM) control module (LH), then go to the next step. (See BLIND SPOT MONITORING (BSM) CONTROL MODULE REMOVAL/INSTALLATION.) |
No |
Go to the next step. |
||
4 |
VERIFY IF OTHER DTCs DISPLAYED
|
Yes |
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [BLIND SPOT MONITORING (BSM) CONTROL MODULE].) |
No |
DTC troubleshooting completed. |