DTC U3000:4B [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
CAUTION:
When replacing a blind spot monitoring (BSM) control module (RH) having any of the following part numbers, it is necessary to replace the blind spot monitoring (BSM) control module (LH) at the same time to perform the configuration normally.
N243-67Y80 A
N243-67Y80 B
N243-67Y80 C
Description |
Temperature temporarily increases depending on various external and environmental factors (blind spot monitoring (BSM) control module (LH) or (RH)) |
Detection condition |
|
Fail-safe |
|
Possible cause |
|
System wiring diagram |
Not applicable |
Step |
Inspection |
Action |
|
1 |
VERIFY BLIND SPOT MONITORING (BSM) CONTROL MODULE INTERNAL TEMPERATURE
|
Yes |
Replace the blind spot monitoring (BSM) control module in which the internal temperature increased, then go to Step 3. (See BLIND SPOT MONITORING (BSM) CONTROL MODULE INSPECTION.) |
No |
Go to the next step. |
||
2 |
VERIFY IF MALFUNCTIONING LOCATION IS BLIND SPOT MONITORING (BSM) CONTROL MODULE (RH) DEPENDING ON REPEATABILITY
|
Yes |
Replace the blind spot monitoring (BSM) control module, then go to the next step. (See BLIND SPOT MONITORING (BSM) CONTROL MODULE INSPECTION.) |
No |
Go to Step 4. |
||
3 |
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes |
Repeat the inspection from Step 1.
Go to the next step. |
No |
Go to the next step. |
||
4 |
VERIFY IF OTHER DTCs DISPLAYED
|
Yes |
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [BLIND SPOT MONITORING (BSM) CONTROL MODULE].) |
No |
DTC troubleshooting completed. |